Bladewerx LogoBladewerx SabrePSC

Portable Alpha Radiation Sample Counter

 

 

Features

  • Bladewerx SabrePSC Alpha Radiation Sample CounterSelf-contained counter

  • 12 hour battery life

  • Uses an alpha radiation peak-shape fitting algorithm that is more accurate than regions-of-interest or tail-fitting methods for radon background compensation

  • Activity determinations for up to two different radioactive isotopes along with full spectrum logging

  • Automatic min-count time determination

  • Live "strip chart" display of activity, detection limit, action level and elapsed time

  • Capable of matching a radionuclide from a user-defined list

  • American or SI units

 

Introduction

 

The Bladewerx SabrePSC™ is a battery-powered field deployable alpha radiation sample counter that provides high sensitivity alpha activity determinations on filters, smears, planchets or swipes, with real time compensation for radon decay products. Samples no longer need to be stored for several days for radon progeny to decay before being able to assess longer-lived activity. Up to two radioactive isotopes-of-interest can be specified for activity measurement during a count. The SabrePSC is easily configured to make activity determinations on most alpha radiation emitting Special Nuclear Materials, and other naturally-occurring radionuclides, and has the unique ability to match an unknown peak to any radionuclide in the user-editable isotope table.


Bladewerx SabrePSC Portable Alpha Radiation Sample CounterRuggedized Construction

SabrePSC is housed in a sealed case and is constructed with a solid metal base plate with interchangeable two-sided sample holders that provide for repeatable sample geometry for 2-inch diameter filters, or filter cards. The movable upper electronics assembly houses the solid-state ion-implanted radiation detector, detector power supply, amplifier, and multi-channel analyzer. A rugged parallelogram hinge moves the detector in and out of position over the sample and protects the detector face, keeping it parallel to lower plate. On the 2-inch detector model, the detector face is protected by a highly open stainless steel mesh.


SabrePSC Assistant Software
The SabrePSC Assistant analysis and control software is a Microsoft Windows Mobile-based application running on the integrated iPAQ PDA that provides complete instrument control, calibration, data analysis, and data logging capabilities. The spectrum analysis and separation of radon decay products is possible through the use of Bladewerx’ acclaimed alpha peak shape fitting algorithm. For simplified energy calibration, the user interface employs simple point and drag operations to position peak locators on the spectral display. Anther time-saving feature is the automatic count time determination mode where, based on user-defined action level and confidence bounds, the instrument sample count is terminated as soon as the user-defined constraints are met. The SabrePSC Assistant software is installed on the integrated iPAQ PDA mounted inside the SabrePSC.

 

Bladewerx SabrePSC Portable Alpha Radiation Sample Counter               Bladewerx SabrePSC Portable Alpha Radiation Sample Counter
 

Alpha Peak-Shape-Fitting
State-of-the-art alpha peak shape fitting is used to separate the spectrum into the contributions from its constituent nuclides and quantify the spectrum counts from radon decay products and the one or two user-defined isotopes-of-interest. Alpha peak shape fitting is a technique that uses the profiles of multiple alpha radiation isotope peaks to create a composite curve which best fits the actual spectrum counts. Because the individual nuclide peaks are independently determined, the separation of nuclides is impervious to the radon equilibrium state or peak ratio changes during the decay process. Precise fitting of the 218Po tail results in excellent resolution of alpha radiation emitters below 5.5 MeV, in many cases allowing the software to resolve 239Pu from 241Am. To learn more about Bladewerx' Alpha Peak Shape Fitting - click here.


The SabrePSC Assistant also includes a “match” mode where each radionuclide in the user editable Isotope List is tested against the spectrum and the isotope with the “best fit” is determined and reported. This feature allows the customer to set the primary isotope-of-interest for the radionuclide of highest likelihood, and let the software test for any other possible activity sources.


Sample Logging
The SabrePSC Assistant software creates a database of the results of each user initiated count—whether the count completed normally, was cancelled, or finished with an activity above the action level. The database uses the comma-separated-variable (*.csv) format, recognized by most spreadsheet and database software.

 

 

Specifications

 

Models

  • SabrePSC with 1” detector: BIN-SABR-PSC-1

  • SabrePSC with 2” detector: BIN-SABR-PSC-2

Detector and Sample Holder

  • Bladewerx SabrePSC Portable Alpha Radiation Sample CounterRadiation Detector: Solid-state ion-implanted silicon
       1-inch detector: 450 mm² active area
       2-inch detector: 2000 mm² active area

  • Standard 2-inch Sample Holder for filters, swipes, smears and planchets supplied

  • Efficiency:
       1-in. detector: 25% (typical)
       2-in. detector with protective mesh: 18%

Data Analysis

  • MCA: 1024-channel ADC binned to 256 channel spectrum

  • Peak-fitting algorithm for 212Po, 214Po, 218Po and two additional radionuclides (e.g. 239Pu and 241Am)

  • Both fixed, and automatic count time modes

  • Automatic Count Time Mode terminates count after activity and detection limit are both below the action level, or if activity is above the action level and reading is within a user-defined confidence level

  • Max Count Rate: 600,000 cpm

  • Source Response Check diagnostic

  • Calibration: Electro-plated stainless steel radioactive source required for efficiency calibration. 241Am or 239Pu recommended.

  • Energy Range: 1.0 - 10.0 MeV

Physical

  • Weight: 20 lbs (9 kg)

  • Dimensions: 19.8”w x 5.4”h x 15.5”d (50 x 14 x 39cm)

  • Temperature: 0 to 122 °F (-20 to 50°C)

  • Humidity: 5 to 100% (non-condensing)

  • Water-tight case

  • Battery: 12-hours run-time per charge. Can be recharged in 3-hours.

  • Charging/Supplemental Input: 12-15 vdc @ 200 mA (AC Adapter supplied, but can be powered/charged by 12 vdc vehicle accessory power)

 

Options

  • SI Units (Bq and Bq/m³): BIN-PSC-OPT2

  • Sample Holder for Whatman and NFS/RPS Cards: BIN-ASC-HOLD3
     

Consumables

 

Spare Parts

  • 4100 mA-h Li-Ion battery: BPT-LION-4100

  • SabreMCA board: BSP-SMCA-A1

  • SabreAux board: BSP-SAUX-A1

  • Sabre preamp board: BSP-PAMP-P1

  • SabrePSC iPAQ (pre-configuration): BPT-IPAQ24-PSC

  • Pump/Battery cable: BSP-CABL-1305

  • Detector, 450 mm²: BPT-DETC-SD450

  • Detector, 2000 mm²: BPT-DETC-SD2000

  • AC adapter/charger (U.S.): BPT-ACADP-1222

 