Ludlum Measurements, Inc.  Ludlum Model 192

   MicroR Radiation Survey Meter

 

 Introduction

     

Ludlum Model 192 MicroR Radiation Survey Meter●  High Sensitivity Gamma MicroR Meter

●  0 to 5000 µR/hr Range

●  Internal 2 x 1 in. NaI(Tl) Scintillation Detector

●  4 Decade Analog Meter

●  Dual Action Alarm

●  Rugged

 

The Ludlum Model 192 is a high-sensitivity gamma radiation MicroR survey meter employing an internally housed 2.0 in. diameter by 1.0 in. thick (5.1 x 2.5 cm) NaI(Tl) detector. This instrument supports two types of alarms: a user adjustable fixed point alarm and a deviation alarm that activates at levels above a floating background. An alarm light is mounted to the front panel and is accompanied by an audio signal. The front-panel controls include a rotary switch for selecting the four-decade range, instrument shut-off and battery test, an audio on/off switch, a fast/slow response switch, and a reset button. The aluminum cast instrument housing with its separate battery compartment and accompanying metal handle offer an industrial robustness and quality that promote long-lasting protection and instrument life. The Model 192 is a complete turn key system and includes two "D" cell batteries.  

 

 Specifications

 

Ludlum Model 192 MicroR Radiation Survey MeterPART NUMBER: 48-2945

APPLICATION: low-level (μR) gamma radiation survey
RANGE: 0-5000 µR/hr (0-50 µSv/h)

RADIATION DETECTOR: 2.0 in. diameter x 1.0 in. thick (5.1 x 2.5 cm) NaI(Tl) scintillator
SENSITIVITY: typically 700 cpm/µR/hr (7 cpm/μSv/h) for 137Cs gamma
ENERGY RESPONSE: energy dependent

LINEARITY: reading within 10% of true value
METER: 2.5 in. (6.4 cm) arc, 1 mA analog type

METER FACE: 0-5 µR/hr, BAT TEST (others available)

ALARM: dual action alarm

Fixed: alarm point that can be set at any point from 10% of full scale to full scale, and is indicated by a constant audible tone, and the lamp turning on.
Deviation: a quick alarm that is based on background radiation levels. When the instrument is turned on, it takes an 8 second measurement of background radiation levels and determines a deviation alarm setting. If the radiation level exceeds this setting, the alarm audio will beep every 1/8 second, and the lamp will flash.

CONTROLS:

Rotary Selector: switches between instrument off, battery check, ranges: x1, x10, x100, x1000

Response Switch: toggles between FAST (4 s) or SLOW (22 s) from 10% to 90% of final reading

Reset Pushbutton: to zero meter, re-accumulate background data and recalculate the alarm point

Audio Switch: for audio on/off, built-in unimorph speaker, greater than 60 dB at 2 ft (0.6 m)

Calibration Controls: accessible from front of instrument (protective cover provided)

TEMPERATURE RANGE: -4 to 122 °F (-20 to 50 °C), may be certified from -40 to 150 °F (-40 to 65 °C) BATTERY LIFE: typically 600 hours with alkaline batteries (battery check on meter)

SIZE: 6 x 3.5 x 7.6 in. (15.2 x 8.9 x 19.3 cm) (H x W x D)
WEIGHT: 5 lb (2.3 kg), including batteries

CE CERTIFIED: yes

 

 Options & Accessories

 

Ludlum Lighted Handle

Ludlum Shoulder Strap

0.25 µCi Cs-137 Radiation Check Source

Ludlum Storm Case

 

Lighted Handle

Shoulder Strap

Check Source

Storm Case

 

 

 Technical Information

 

Data Sheet

Product Manual

CE Certificate

MicroR Meter Sensitivity Chart

 

 Ludlum Resources

 

About Ludlum

Product Catalogs & Price Lists

Standard & Extended Warranty

Software Downloads

Replacement Parts

Repair & Calibration

Training