Ludlum Measurements, Inc.  Ludlum Model 2100-1

  Radiation Sample Counter

 

 Introduction

 

Ludlum Model 2100-1 Radiation Sample Counter●  Manually Operated Gamma Radiation Sample Counter

●  High Sensitivity 2 x 2 in. NaI(Tl) Scintillation Detector

●  Separate High and Low Gamma Energy Sampling

●  Table-Mounted, Fully Integrated Design

●  Manually Operated Sample Tray

●  User Adjustable Parameters

●  Ethernet Connectivity

●  Color LCD Touch Screen

●  Remote Alarm Output

●  USB Ports for ID Input Devices

 

The Ludlum Model 2100-1 manually operated radiation sample counting system processes sample steel slugs to determine whether any radioactive impurities exist.  The gamma radiation counting system is a table-mounted, fully integrated design that includes a gamma detector, sample tray, and controller. The counting electronics incorporates two channels to distinguish between low and high energy gamma isotopes.  All parameters, such as alarm point and count time are user-adjustable from the front panel LCD touch screen via a simple menu selection. Measurement results for each sample are displayed on the backlit LCD.  An Ethernet port reports all results and system status in real time for remote data logging and alarm annunciation.  Visual and audible alarms are annunciated via the system’s LCD and rear panel mounted buzzer respectively.  A built-in relay provides a method for driving an external horn/strobe (available as an option).  Ludlum also offers an optional Ethernet-based Model 272E remote display for conveniently displaying of one or more sample counters. One rear panel mounted USB port enables connection to either a keyboard or barcode reader device for the purpose of entering sample ID’s.
 

 Specifications

 

PART NUMBER: 48-3781

APPLICATION: manual gamma radiation sample counting

RADIATION DETECTOR: 2 x 2 in. (5.1 x 5.1 cm) NaI (sodium iodide)
E
NERGY RESPONSE: 30 keV to 3 MeV
SENSITIVITY: 0.1 Bq/g in less than one minute (standard 100 gram sample) (60Co)
LEAD SHIELDING:  internal lead shielding of 1.5 in. (3.8 cm) surrounds the detector chamber
BACKGROUND: ~1200 cpm in the sum channel

DETECTOR CHAMBER: 2.75 x 0.5 in. (7 x 1.3 cm) (D x H)

AUDIBLE BUZZER: 68 dB at 2 ft (61 cm)
POWER: 95-150 Vac, 50/60 Hz, 120 W
SIZE: 14.5 x 11 x 19 in. (36.8 x 27.9 x 48.3 cm) (H x W x L)
WEIGHT: approximately 55 lb (24.9 kg)

 

 Options & Accessories

 

Ludlum Model 2100 Gamma Radiation Sample Counter

Ludlum Model 272E Remote Display Ludlum Model L-2433-504 Simulated Co-60 Radioactive Source    

Model 2100 Automatic Conveyor Version

Model 272E

Remote Display

Part Number

4396-1081

Simulated Co-60

Calibration Source

Part Number

2433-504

   

 