Ludlum Measurements, Inc.  Ludlum Model 3030E with Model 43-10-1

   Alpha/Beta Radiation Sample Counter

 

 Introduction

 

Ludlum Model 3030E with Model 43-10-1 Alpha Beta Radiation Scaler●  Alpha/Beta Sample Counter with External Detector

●  Simultaneous Alpha and Beta Radiation Counting

●  Utilizes ZnS(Ag) on Plastic Scintillation Detector

●  CPM and DPM Modes

●  Background Subtraction

●  Independent Readouts and Alarms

●  8 Hour Battery Operation

●  RS-232 Interface

●  Includes PC Software

 

This system joins Ludlum's Model 3030E dual channel radiation scaler with its Model 43-10-1 dual phosphor radiation detector/2 in. (5.1 cm) diameter sample tray to produce a complete alpha beta radiation sample counting system. The Model 3030E electronics incorporates independent backlit LCD readouts to support discriminated alpha and beta sample counting. The system features background subtraction, crosstalk correction, separate alpha/beta radiation alarms, CPM/DPM operating modes, and a pre-scripted QC function with automatic reminder timer. The instrument supports both 110 and 220 VAC operation and includes a trickle charged gel-cell battery for portable offsite use up to 8 hours. A wide range high voltage power supply supports virtually any detector. Status indicators located along the front panel inform the operator when another QC check is required, if the detector is non functional, if it's operating in DPM or CPM mode, and if either an alpha or beta radiation alarm setpoint has been exceeded.

 

 Specifications

 

PART NUMBER: 48-3456

APPLICATION: simultaneous alpha beta radiation sample counting
RADIATION DETECTOR: ZnS(Ag) adhered to plastic scintillation disk

PHOTOMULTIPLIER TUBE: 2 in. (5.1 cm) diameter
WINDOW: 0.4 mg/cm2 aluminized Mylar
ACTIVE and OPEN AREA: 20.3 cm2
SAMPLE HOLDER: brass housing with nickel plated brass sample tray capable of holding a 1 in. (2.5 cm) or 2 in. (5.1 cm) diameter sample up to 0.4 in. (1.02 cm) thick
EFFICIENCY(4π): alpha: 32% - 230Th; 39% - 238U; 37% - 239Pu; beta: 5% - 14C; 27% - 99Tc; 29% - 137Cs; 26% - 90Sr/90Y

CROSS TALK: alpha to beta: 10% or less; beta to alpha: 1% or less

BACKGROUND: alpha: 3 cpm or less; beta-gamma: typically 80 cpm or less (10 μR/hr field)

SOFTWARE: PC based to perform setup and calibration routines including background subtract, crosstalk correction, cpm/dpm modes, daily QC check parameters, alarm levels, and automatic plateaus. All parameters are stored in the instrument in non-volatile memory. The supplied software is capable of logging and storing the following: Sample Number, Sample Date, Sample Time, Alpha Count, Beta Count, Sample Type, Comments

ELECTRONICS:

size: 9.5 x 5.3 x 10.0 in. (24.1 x 13.5 x 25.4) (H x W x D)

weight: approximately 6 lb (2.7 kg)

COUNTER HEAD:

size: 9.3 x 4.5 x 9.3 in. (23.6 x 11.4 x 23.6 cm) (H x W x L)

weight: 4.1 lb (1.9 kg)

CE CERTIFIED: yes

 

 Options & Accessories

 

Th-230 Radioactive Check Source

Tc-99 Radioactive Check Source

Ludlum Sample Planchets

   

230-Th Source

Model CS-10

99-Tc Source

Model CS-13

Sample Planchets

   

 

 Technical Information

 

Data Sheet

Product Manual

CE Certificate

PC Software

 