Ludlum Model
375-600
Digital Area Radiation
Monitor
Features
-
Integrated
Measurement System
-
630 in³ Plastic Scintillator
Radiation Detector
-
1/8" Lead Shielding on 5 Sides
-
Model 375 Controller
-
Alarm Strobe
-
Environmental Enclosure
-
Programmable Alarms
-
Networkable
-
Battery Backup
Introduction
The Ludlum
Model 375-600 is a highly integrated, high sensitivity gamma radiation
measurement system. Unlike other systems where the detectors are separated from
the controller and alarm indicators, this one combines all components into one
convenient package thus making installation a lot simpler and less costly. The
detector employed is a 630 in3 plastic radiation scintillator which is shielded in all
directions except beneath with 1/4" lead. The controller is Ludlum's popular
Model 375 digital controller which is located at one end of the cabinet. A red
strobe is mounted on the top along with a large, industrial strength alarm
acknowledgement pushbutton. The detector is accessible from a removable panel
and the entire system sits on a plate which can be bolted to the floor. See
Model 375
for additional detail.
Specifications
PART NUMBER: 48-3458
INDICATED USE: Area
radiation monitoring
RADIATION DETECTOR: 630 in³ shielded plastic scintillation
DIMENSIONS: 15" (38cm) X 28"(71cm) X 1.5" (3.8cm)
SHIELDING: 0.125" lead on five sides
SENSITIVITY:30 kcpm/µR/hr (137Cs)
DISPLAY: 4 digits LED display with 0.8" (2cm) digits
DISPLAY UNITS: kcpm
LINEARITY: Reading within ± 10% of true value with detector connected
RESPONSE: Typically 3 seconds from 10% - 90% of final reading
STATUS: (Green Light) instrument functioning properly
HIGH ALARM: Indicated by red 5 inch diameter xenon strobe, red HIGH ALARM
light, and fast beep (4 per second) audible tone (can be set at any
point from 0.0 - 9999)
LOW ALARM: Indicated by yellow LOW ALARM light and slow beep (1 per
second) audible tone (can be set at any point from 0.0 - 9999)
NOTE:
Audible alert and alarm indicators can be configured as a single beep if
desired
DETECTOR FAIL: (red light and audible tone; greater than 68 dB at 2 feet)
indicates detector overload, no count from detector, or instrument failure
LOW BAT: (yellow) indicates less than 2 hours of battery power
remaining
DEAD TIME: Adjustable to compensate for dead time of detector and
electronics (can be read on display)
OVERLOAD: Senses detector saturation (indicated by display reading "-OL-")
OVERRANGE: Indicates radiation field being measured has exceeded counting
range of instrument (indicated by display reading "----"
DATA OUTPUT: 9 pin connector providing 5 decade logarithmic output,
RS-232 output, signal ground connection, FAIL and ALARM signals (current
sink), and direct connection to battery and ground, relay outputs available
CALIBRATION CONTROLS: Accessible from front of instrument (protective
cover provided)
POWER: 95 - 135 VAC (178 - 240 VAC available), 50-60 Hz single
phase (less than 100 mA), 6 volt sealed lead-acid rechargeable battery
(built in)
BATTERY LIFE: Typically 8 hours in non-alarm condition
BATTERY CHARGER: Battery is continuously trickle-charged when instrument
is connected to line power and turned on
CONSTRUCTION: Steel housing with ivory powder coat paint
TEMPERATURE RANGE: 5° F(-15° C) to 122° F(50° C)
May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 2’(61cm)H X 3’(91.5cm)W X 1’(30.5cm)D chassis size
WEIGHT: 125 lbs (57 kg)
This Product is CE Certified
Technical Information
Other Ludlum Products
Ludlum Information
For more information or to request a quotation,
please contact us
by phone at: (865)
947-5123 or by email at:
sales@deqtech.com.
|