The Ludlum Model 52-5-1
Radiation Portal Monitor is used for Beta/Gamma personnel radiation
contamination monitoring and meets the FEMA standard for Emergency Response
Portal Monitoring (FEMA-REP-21). It is designed to be disassembled for ease of
transportation and storage, and can be set up in under 5 minutes or less without
any tools. The non-volatile parameters are preset at the factory to detect a 1.0
uCi Cs-137 source in a 10 uR/hr background field. The electronics are
microprocessor-based for ease of setup and reliability. Status LEDs indicate
count cycle status. Audible signals accompany the LEDs for additional
indication. Detector counts, background, and all parameters may be viewed on the
Liquid Crystal Display (LCD). All setup is accomplished by way of pushbuttons
located below the LCD. These portal monitors can be operated in a walk-through
basis with a quick scan occurring while a person is positioned within the
portal.
Specifications
PART NUMBER: 48-3571
INDICATED USE: Portable personnel radiation monitoring
RADIATION DETECTORS: 4 ea. 168 cubic inches, plastic scintillators plus 1
ea. 108 cubic inches, plastic scintillator for feet
THRESHOLD: 5 ± 1 mV
DISPLAY: 2 line X 20 character LCD shows background rates from all
detectors, and sigma values above background. To extend battery life, the LCD
backlight on the display has been configured to go OFF when the instrument is on
battery power.
ALARM: Indicated by red LED, and audible signal (greater than 60 dB at 2
feet)
COUNT TIME: Adjustable from 0 - 20 seconds (0 second setting is for
walk through mode)
ENTER/CHECKING: (green LED) Indicates system is ready for use.
Flashing LED indicates a count is in progress.
INCOMPLETE/UPDATING: (amber
LED) Indicates the user has stepped out of the portal before counting was
completed, or that an update is in progress.
FAILURE: (red LED) Indicates a high or low background
INFRARED SENSOR: A retro-reflective sensor senses portal occupancy
PARAMETERS: All parameters are stored in non-volatile memory
OUTPUT: RS-232 output for printer and relay output connectors located on the
bottom of the electronics chassis
POWER: 85 - 250 VAC, 50 - 60 Hz single phase (less
than 100 mA); or 3 ea. "D" cell batteries.
BATTERY LIFE: Typically 24 hours in a non-alarm condition
CONSTRUCTION: Weather-tight housing
TEMPERATURE RANGE: +5° F(-15°C) to 122° F(50° C)
SIZE: 84"(213cm)H X 32"(81cm)W X 36"(91cm)D
PORTAL DIMENSIONS: 81"(206cm)H x 32"(81cm)W*
WEIGHT: 80 lbs (36kg) with bag
SHIPPING WEIGHT: 110 lbs (50kg)
This Product is CE Certified