Ludlum Measurements, Inc. Logo  Ludlum Model 53

  Personnel Gamma Radiation Portal Monitor

 

Ludlum Model 53 Personnel Gamma Radiation Portal MonitorFeatures

  • Large plastic scintillator radiation detectors for optimized detection efficiency

  • Fast Alarm/Fast Clean counting technology for shorter counting cycles

  • Customized voice prompts

  • Three counting modes to maximize throughput, maximize sensitivity, or fix the count time

  • Three user modes: Walk-Thru, Pause, Pause-and-Turn

  • Automatic background updating

  • Recount and contaminated detector check options

  • Individual detector and sum channel alarms

  • Informative 9 in (22.9 cm) color LCDs at ingress and egress

  • PIR (Passive Infrared) sensor to sense personnel approach

  • Photoelectric sensor to detect personnel presence

  • Two levels of password security

  • 1 in (2.5 cm) thick lead shielding, with option for 2 in (5.1 cm)

  • Single Board Computer (SBC) running Windows XP  Operating System

  • Additional USB (Universal Serial Bus) connectors to transfer information from the system, or for input of user ID etc.

  • Ethernet connectivity

  • Option for implementing transmission factors according to user's weight

 

Introduction

 

Ludlum Model 53 Personnel Gamma Radiation Portal MonitorThe newly designed Ludlum Model 53 Personnel Gamma Radiation Portal detects gamma radiation in or on personnel passing through the portal from either direction.  This highly sensitive portal uses eight large plastic scintillation detectors, and is shielded with either the standard 1 in (2.5 cm) or optional 2 in (5 cm) of lead.  A user-friendly interface guides personnel through the portal monitor via automated voice prompts, and is accompanied with 9 in (22.9 cm) color LCD articulating screens presenting the instrument readiness and status at the ingress and egress. Alarms are manifested both audibly and visually, and can be silenced and acknowledged via a control button located on either side of the instrument.

 

Ludlum Model 53 Personnel Gamma Radiation Portal MonitorThree statistical counting modes are available to maximize throughput, maximize sensitivity, or fix the count time.  Several modifiable parameters adjust the alarm set point, including the false alarm probability, detection probability, background sigma coefficient (KB), and the composite sigma coefficient (KS+B).  Fast alarm and clean options provide the ability to quickly determine if personnel are contaminated or clean before the entire count cycle has ended.

 

Ludlum Model 53 Personnel Gamma Radiation Portal MonitorOperational modes include a walk-through mode, a pause mode, and a pause-and-turn mode.  Voice prompts may be customized in any language for each of these modes.  These prompts can, for example, dictate in-house procedures to follow.  Instrument technicians have password-protected access to set up the instrument, and to  the advanced automated routines for calibrating and verifying operation.

 

Easily accessible USB ports facilitate connecting a keyboard to implement changes, input user ID, or upload revised software.  The system also includes an Ethernet link.  Ludlum's optional Universal network software can be used to log instrument status, user activity, and other information from one or more  instruments connected to the network. This software broadcasts emails whenever radiological alarms or instrument failures occur, and has the ability to capture images from network cameras that can be stored along with the user ID (if implemented).
 

Ludlum Model 53 Personnel Gamma Radiation Portal MonitorA unique feature, not found anywhere else, is an optional weight scale that assesses the weight of the individual passing through the portal and then assigns an appropriate transmission factor for a more accurate gamma measurement.  Other options include  an additional 1 in (2.5 cm) of lead shielding, a second alarm/light stack, and the Universal network software.


 

Specifications

 

PART NUMBER: 48-3151

INDICATED USE: gamma personnel monitoring
RADIATION DETECTORS: 8 identically-sized plastic scintillators (3 on each side, one overhead, one under feet)
Scintillator Type: EJ-200
Size: 19 x 19 x 2 in (48.26 x 48.26 x 5.08 cm) (H x W x D)
Volume: 5655 in³ total (92668 cm³)
Shielding: 1 in (2.5 cm) standard, 2 in (5.1 cm) optional
 
SENSITIVITY: will detect between 10-100 nCi depending upon the background, isotope, and the selected operational mode, count time, confidence level etc.
 
OPERATION: bi-directional walk through
Operating Modes: Walk-Thru, Pause, Pause-and-Turn
Counting Modes: maximized throughput, maximized sensitivity, or fixed count time
Status Conditions: ready, door open, clean, counting, alarm, high alarm, failure, updating background, extending background, initializing, contamination check, contaminated
Voice Commands: can be customized to any language and in-house procedure
 
CONTROLS/DISPLAYS
Displays: dual 9 in (22.9 cm) color screen LCDs mounted to an articulating arm for optimized viewing, one on ingress, the other on the egress side
Alarm Acknowledge: single button on the ingress/egress sides that silence and clear any alarm
Portable Keyboard: USB plug-in keyboard with convenient mounting bracket to facilitate setup, parameter editing and calibration functions, included with instrument
Light Stack/Audio Annuciator: green (operational), yellow (warning), red (alarm) lights display instrument status, audio output is 70-85 dB at 1 meter, mounted to either the ingress or egress sides (egress standard), a second light stack is available as an option
 
ELECTRONICS:
Central Processor: Single Board Computer (SBC) running Windows XP  Operating System
Detector Signal Conditioning: Ludlum's single detector board technology located on each detector assembly
Proximity Sensors:
PIR (Passive Infrared) sensor to sense personnel approach
Photoelectric sensor to detect personnel presence
Interfaces:
USB Ports: 2 per side (ingress/egress) for connecting plug-in keyboard or user ID devices
Ethernet connection: supports centralized and distributed viewing of instrument operation. Optional Ludlum Universal network software connects several Ludlum instruments (including different types) to a common radiological network for performing data logging, remote alarm notification, email notification, and image capturing upon an alarm.
 
MECHANICAL:
Construction: aluminum construction with ivory and brown powder coat paint
External Dimensions:
86 x 34.5 x 30 in (205.7 x 94 x 53.3 cm) (H x W x L), ramp extends 17 in (43.2 cm) per side, LCD monitors protrude 5 in (12.7 cm) per side
Portal Opening Dimensions: 77 x 24 in (195.6 x 61 cm) (H x W)
Portal Step: 4 in high (10.2 cm)
Detector Doors/Covers: 0.060 in (15.2 mm) aluminum
Weight:
less lead shielding: 635 lb (288 kg)
1 in (2.5 cm) Pb: additional 1600 lb (726 kg)
2 in (5.1 cm) Pb: additional 2800 lb (1270 kg)
 
TEMPERATURE RANGE: 32 to 122 °F (0 to 50 °C)

POWER: 85–250 Vac, 50–60 Hz

 

 

Technical Information

 

Units shipped 2010 and after (part Number: 48-3784)

Units shipped 2009 and earlier (Part Number: 48-3151)

 