Ludlum Measurements, Inc. Logo  Ludlum Model 9-4

  Air Ionization Chamber Radiation Survey Meter

 

Ludlum Model 9-4 Air Ionization Chamber Survey MeterFeatures

  • 5 Ranges from Background to 50 R/hr

  • 1000 mg/cm2 Retractable Beta Shield

  • Automatic Temperature and Pressure Compensation

  • Low Battery Warning

  • High Background Zero Capability

  • PC-Controlled Calibration

 

Introduction

 

The Ludlum 9-4 is a rugged air ionization chamber for performing beta-gamma radiation dose rate measurements over a 5 decade span ranging from background to 50 R/hr. The ion chamber automatically compensates for changes in temperature and pressure.  The chamber wall, including the instrument case, is 1000 mg/cm2. A 1000 mg/cm2 retractable beta shield allows beta measurement with a 7 mg/cm2 window.
 
The six position selector switch selects Off, x10K, X1K, X100, X10 and X1.  Other controls include an on/off switch for a meter light, reset and battery test buttons and a zero adjustment knob.
 

The Model 9-4 is equipped with a serial interface for calibration.  An optional calibration kit is available that supplies the necessary interface cable, software, calibration can, pressure pump and serial-to-USB converter.

 
 

Specifications

 

PART NUMBER: 48-3739

APPLICATION: Gamma and X-ray radiation exposure survey meter with beta response
RANGE: 0 - 50 R/hr
ENERGY RESPONSE: +/- 20% of true value from 40 keV - 2 MeV
LINEARITY: Reading within 10% of true value
RESPONSE TIME: Approximately 5 seconds for 90% of final meter deflection on the x1 and x10 scales, and 3 seconds on the x100, x1k and x10k scales
BETA RESPONSE: Factor of 4.8 difference between window open and closed measurements when exposed to a uranium slab
CHAMBER VOLUME: 220 cm³
CHAMBER CONSTRUCTION: Carbon coated acrylic
SIDE WALL: 1000 mg/cm² aluminum and acrylic
BETA SHIELD: Retractable 1000 mg/cm² phenolic slide with side button control
WINDOW: 7 mg/cm² aluminized mylar
WINDOW AREA: 40 cm²
COMPENSATION: Automatically corrects for temperature and pressure changes in atmosphere
TEMPERATURE RANGE: -4°  to 122° F (-20° to 50° C). Temperature compensation maintains calibration within 15% of 25° C reading
PRESSURE COMPENSATION RANGE: 70 kPa to 106 kPa
METER: 2.5” (6.4 cm) arc, 1 mA, pivot-and jewel suspension
METER DIAL: 0 - 5 mR/hr, BAT TEST
CONTROLS:
  • Range Switch: 5 range multipliers x1, x10, x100, x1k, x10k and instrument off
  • Reset: Pressing the reset button causes the chamber to discharge
  • Bat Test: Pushbutton used to check battery capacity
  • Zero Adjust: 1 turn potentiometer to zero reading
  • Display Light: On/off switch
  • Calibration: Digitally set via USB to serial computer interface, stored in non-volatile memory
POWER: 2 each “D” cell batteries housed in a sealed externally-accessible compartment
BATTERY LIFE: 400 hours
CONSTRUCTION: Cast and drawn aluminum with beige powder-coating
SIZE: 9.2” H x 3.5” W x 8.5” L (23.4 x 8.9 x 21.6 cm) including instrument handle
WEIGHT: 4.2 lbs (1.9 kg) including batteries

 

 

Meter Face

 

Ludlum Model 9-4 Meter Face

 