Ludlum Medical Physics  Ludlum Medical Physics Model 193-6

  Floor Radiation Survey Monitor

 

 

FeaturesLudlum Medical Physics Floor Radiation Monitor - Model 193-6

  • 4 Ranges

  • Automatically Adjusting Alarm Setting

  • Micro-processor based

  • 6" X 1" Plastic Gamma Scintillator

 

Introduction

 

The Ludlum Model 193-6 Floor Radiation Survey Monitor may be used for a variety of medical and health physics applications and is ideal for low level (microR) measurement of real or suspected radiation spills in a variety of environments. 

This instrument design utilizes a highly sensitive 6” diameter plastic scintillation detector which makes short work of confirming (or clearing)  the presence of radionuclides in an  isotope laboratory or  nuclear medicine work area.  The detection range is from background up to 1000 uR/hr.

Attached to the user-end of the pole is a 4 decade analog ratemeter employing an aluminum cast instrument housing with a separate battery compartment and accompanying metal handle. The overall design delivers industrial robustness and quality that promote long lasting protection and instrument life.
 

 

Specifications

 

PART NUMBER: 48-3063

INDICATED USE: Low level (microR) gamma radiation survey
ALARM: The analog ratemeter has a dual action alarm:
1. A fixed alarm point that can be set at any point from 10% of full scale to full scale, and is indicated by a constant audible tone, and the lamp turning on.
2. A quick deviation alarm that is based on background radiation levels. When the instrument is turned on, it takes an 8 second measurement of background radiation levels and determines a deviation alarm setting. If the radiation level exceeds this setting, the alarm audio will beep every 1/8 second, and the lamp will flash.
RESET: Push button to zero meter, and also re-accumulate background data and recalculate the alarm point.
BATTERY LIFE: Typically 600 hours with alkaline batteries (battery condition can be checked on meter)
DETECTOR: 6" diameter x 1" thick (15.2 x 2.5 cm) plastic scintillator
SENSITIVITY: Typically 2000 cpm/uR/hr (137Cs gamma)
METER DIAL: 0 - 1 uR/hr, BAT TEST (others available)
RANGE MULTIPLIERS: X1, X10, X100, X1000
ENERGY RESPONSE: Energy dependent
HIGH VOLTAGE: Fixed based on detector
WEIGHT: 8.5 lbs. (3.9 kg) including batteries

 

 